Waste and rain water reuse
-
ABOVE-AUTO

Dimensioned according to the R.D. 1620/2007 norm.
Reuse system with :
REUSE STATION composed with: galvanize steel structure with high productivity filter, automatic cleaning, sand/flint/anthracite loading, electro-valve, pressure gauge, ring filter, cartridge filter, supply point valve, UV light and sensor, colouring pump and tank.
POWER SUPPLY SYSTEM FOR REUSE STATION composed with: auto-suction pumps, preliminary level regulator, lock valve, pressure gauge and check valve.
CLEAN WATER TANK MAINTENANCE composed with: auto-suction pumps, automatic chlorine station, level regulator, check valve and disinfecting agent tank.
ROUGH WATER COLLECTING TANK composed with: FGRP (Fiber Glass Reinforced Polyester) tank, place above ground, inlet outlet, draining and excess pipes, retention basket (optional)
CLEAN WATER TANK composed with: FGRP (Fiber Glass Reinforced Polyester) tank, place above ground, inlet, outlet, draining and recirculation pipes and level regulator.
ELECTRIC BOARD.
-
ABOVE-MANUAL

Dimensioned according to the R.D. 1620/2007 norm
Reuse system composed with:
REUSE STATION composed with: galvanize steel structure with high productivity filter, manual cleaning, sand/flint/anthracite loading, pressure gauge, ring filter, cartridge filter, supply point valve, UV light and sensor, colouring pump and tank.
POWER SUPPLY SYSTEM FOR REUSE STATION composed with: auto-suction pumps, automatic chlorine station, preliminary level regulator, lock valve, pressure gauge and check valve.
CLEAN WATER TANK MAINTENANCE composed with: auto-suction pumps, automatic chlorine station, level regulator, lock and check valve and disinfecting agent tank.
ROUGH WATER COLLECTING TANK composed with: FGRP (Fiber Glass Reinforced Polyester) tank, place above ground, inlet outlet, draining and excess pipes, retention basket (optional)
CLEAN WATER TANK composed with: FGRP (Fiber Glass Reinforced Polyester) tank, place above ground, inlet, outlet, draining and recirculation pipes and level regulator.
ELECTRIC BOARD.
-
UNDER-AUTO
Dimensioned according to the R.D. 1620/2007 norm
Reuse system composed with :
REUSE STATION composed with: galvanize steel structure with high productivity filter, automatic cleaning, sand/flint/anthracite loading, electro-valve, pressure gauge, ring filter, cartridge filter, supply point valve, UV light and sensor, colouring pump and tank.
POWER SUPPLY SYSTEM FOR REUSE STATION composed with: submerge pump, level regulator, lock valve, pressure gauge and check valve.
CLEAN WATER TANK MAINTENANCE composed with: auto-suction pumps, automatic chlorine station, level regulator, pressure gauge, lock and check valve and disinfecting agent tank.
ROUGH WATER COLLECTING TANK composed with: FGRP (Fiber Glass Reinforced Polyester) tank, place underground, inlet outlet, and draining pipes.
CLEAN WATER TANK composed with: FGRP (Fiber Glass Reinforced Polyester) tank, place underground, inlet, outlet, draining and recirculation pipes and level regulator.
ELECTRIC BOARD.
-
UNDER-MANUAL
Dimensioned according to the R.D. 1620/2007 norm
Reuse system composed with:
REUSE STATION composed with: galvanize steel structure with high productivity filter, manual cleaning, sand/flint/anthracite loading, pressure gauge, ring filter, cartridge filter, supply point valve, UV light and sensor, colouring pump and tank.
POWER SUPPLY SYSTEM FOR REUSE STATION composed with: submerge pumps, level regulator, lock valve, pressure gauge and check valve.
CLEAN WATER TANK MAINTENANCE composed with: auto-suction pumps, automatic chlorine station, level regulator, lock and check valve, pressure gauge and disinfecting agent tank.
ROUGH WATER COLLECTING TANK composed with: FGRP (Fiber Glass Reinforced Polyester) tank, place underground, inlet outlet, and excess pipes.
CLEAN WATER TANK composed with: FGRP (Fiber Glass Reinforced Polyester) tank, place underground, inlet, outlet, draining and recirculation pipes and level regulator.
ELECTRIC BOARD.
Purify industrial waste water reuse for vehicles industrial cleaning
-
UNDER-AUTO-CAR

Dimensioned according to the R.D. 1620/2007 norm
Reuse system composed with :
REUSE STATION composed with: galvanize steel structure with high productivity filter, automatic cleaning, sand/flint/anthracite loading, electro-valve, pressure gauge, ring/cartridge/activated-coal filter with automatic cleaning system, activated coal load, supply point valve, UV light and sensor.
POWER SUPPLY SYSTEM FOR REUSE STATION composed with: submerge pump, level regulator, lock valve, pressure gauge and check valve.
CLEAN WATER TANK MAINTENANCE composed with: auto-suction pumps, automatic chlorine station, level regulator, pressure gauge, lock and check valve, pressure gauge and disinfecting agent tank.
ROUGH WATER COLLECTING TANK composed with: FGRP (Fiber Glass Reinforced Polyester) tank, place underground, inlet outlet, and excess pipes.
CLEAN WATER TANK composed with: FGRP (Fiber Glass Reinforced Polyester) tank, place underground, inlet, outlet, draining and recirculation pipes and level regulator.
ELECTRIC BOARD.
Disinfection system
-
EST-AUT-REDOX
Flow measure pump proportionally to the redox average.
-
EST-AUT-REDOX-PH
Acid and chlorine measure pump proportionally to the pH and the redox average.
-
EST-AUT-CLORO
Chlorine measure pump, flow proportional to the free chlorine average.
-
EST-AUT-CLORO-PH
Acid and chlorine measure pump, flow proportional to the pH and the chlorine average.
-
EST-AUT-CLORO-DIGITAL
Free chlorine regulator with graphic LCD display, measure from 0 to 30 mg/l, on/off or time-switch proportionally instruction point.
-
EST-AUT-CLORO-PH-DIGITAL
Free chlorine and pH regulator with graphic LCD display, measure from 0 to 14pH and from 0 to 10 mg/l, on/off or time-switch proportionally instruction point.
-
EST-AUT-CLORO-LIN
Chlorine station, for pipe insertion, composed with:
Measure pump with impulse frequency regulation, proportional to the flow and controlled by an impulse counter-transmitter. The carcass and the hydraulic, composed with valves and membranes, will be constituted with material compatible with the disinfecting agent.
Water counter-transmitter with impulse transmitter for pipe’s insertion
-
EST-UV
-
CVC-CE
Residual water disinfection to eliminate pathogen germs and reuse the water.
Auxiliaries components
-
RAP
Rain water filtration and storage for a watering reuse.
|